Product Details:
Payment & Shipping Terms:
|
Manufacturer: | Pepperl+Fuchs | Product No: | KFA6-DWB-EX1.D |
---|---|---|---|
Product Type: | Rotation Speed Monitor | Connection: | Terminals 23, 24 |
Rated Voltage: | 230 V AC ± 10 % | Rated Current: | 18 MA |
Leading Time: | Negotiable | Shipping Weight: | 1 Kg |
High Light: | KFA6-DWB-EX1.D Rotation Speed Monitor,PEPPERL FUCHS Rotation Speed Monitor,230VAC Rotation Speed Monitor |
Manufacturer : Pepperl+Fuchs
Product No : KFA6-DWB-EX1.D
Product type : Rotation Speed Monitor
230 V AC supply
Dry contact or NAMUR inputs
Input frequency 1 mHz ... 5 kHz
2 relay contact outputs
Start-up override
Configurable by keypad
Line fault detection (LFD)
Up to SIL2 acc. to IEC 61508/IEC 61511
Signal type : Digital Input
Rated voltage Ur : 230 V AC ± 10 %
Ambient temperature : -20 ... 60 °C (-4 ... 140 °F)
Degree of protection : IP20
Dimensions : 4 x 11.9 x 11.5 cm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Mass : 0.3 Kg
Shipping Weight : 1.5 kg
This isolated barrier is used for intrinsic safety applications. It monitors for an overspeed or underspeed condition of a discrete signal (NAMUR sensor/ mechanical contact) from a hazardous area by comparing the input frequency to the user programmed reference frequency.
An overspeed or underspeed condition is signaled via the relay outputs. Line fault detection of the field circuit is indicated by a red LED and relay.
Product Description | ||
---|---|---|
230 V AC |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | terminals 23, 24 | |
Rated voltage | 230 V AC ± 10 % | |
Rated current | 18 mA | |
Power dissipation/power consumption | ≤ 2 VA / 2 VA | |
Input | ||
Connection side | field side | |
Connection | Input I: intrinsically safe: terminals 1+, 3- Input II: non-intrinsically safe: terminals 13+, 14- |
|
Input I | acc. to EN 60947-5-6 (NAMUR) | |
Pulse duration | > 50 µs | |
Input frequency | 0.001 ... 5000 Hz | |
Line fault detection | breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA | |
Input II | startup override: 1 ... 1000 s, adjustable in steps of 1 s | |
Active/Passive | I > 4 mA (for min. 100 ms)/ I < 1 mA | |
Open circuit voltage/short-circuit current | 18 V / 5 mA | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 |
|
Output I, II | signal, relay | |
Contact loading | 253 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A | |
Mechanical life | 5 x 107 switching cycles | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Transfer characteristics | ||
Input I | ||
Measurement range | 0.001 ... 5000 Hz | |
Resolution | 0.1 % of measured value , ≥ 0.001 Hz | |
Accuracy | 0.1 % of measured value , > 0.001 Hz | |
Measuring time | < 100 ms | |
Influence of ambient temperature | 0.003 %/K (30 ppm) | |
Output I, II | ||
Response delay | ≤ 200 ms | |
Galvanic isolation | ||
Input I/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Output I, II against eachother | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Start-up override/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | TÜV 99 ATEX 1408 | |
Marking | ![]() ![]() ![]() |
|
Supply | ||
Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) | |
Input I | terminals 1+, 3-: Ex ia | |
Voltage |
10.1 V | |
Current |
13.5 mA | |
Power |
34 mW (linear characteristic) | |
Input II | terminals 13+, 14- non-intrinsically safe | |
Maximum safe voltage |
40 V (Attention! The rated voltage can be lower.) | |
Output I, II | terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe | |
Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) | |
Contact loading | 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load | |
Certificate | TÜV 02 ATEX 1885 X | |
Marking | ![]() |
|
Output I, II | ||
Contact loading | 50 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load | |
Galvanic isolation | ||
Input I/other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 16-538FM-12 | |
UL approval | E223772 | |
IECEx approval | ||
IECEx certificate | IECEx TUN 03.0000 | |
IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
·1-channel isolated barrier
·230 V AC supply
·Dry contact or NAMUR inputs
·Input frequency 1 mHz ... 5 kHz
·2 relay contact outputs
·Start-up overridev
·Configurable by keypad
·Line fault detection (LFD)
·Up to SIL 2 acc. to IEC 61508/IEC 61511
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with us.
Contact Person: Zoey Zeng
Tel: +8615677087092