logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022

Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022

MOQ: 1pcs
Price: Negotiable
Standard Packaging: Original packing
Delivery Period: On request
Payment Method: T/T
Supply Capacity: 5000pcs/month
Detail Information
Place of Origin
DE
Brand Name
Endress Hauser
Certification
Rohs
Model Number
CLS54-AAA5022
Measurement Range:
100 µS/cm - 2000 MS/cm Cell Constant K: 6,3 1/cm
Process Temperature:
-10°C - +125°C
Sterilisation:
150°C/5 Bar (max. 60 Min.)
Process Pressure:
12 Bar(174 Psi)/20°C(68°F)
Measuring Principle:
Inductive Conductivity Measurement
Highlight:

Indumax analog electrical conductivity sensor

,

CLS54 analog electrical conductivity sensor

Product Description

Analog Conductivity Sensor Indumax CLS54 E&H Instrument CLS54-AAA5022

Process pressure

12 bar(174 psi)/20°C(68°F)

Ingress protection

IP68/NEMA6P

Measuring principle

Inductive conductivity measurement

 

Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022 0Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022 1

 

Specs at a glance

  • Measurement range

    100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm

  • Process temperature

    Process temperature: -10°C - +125°C
    (14°F - 257°F)
    Sterilisation: 150°C/5 bar (max. 60 min.)
    (302°F / 72.5 psi)

  • Process pressure

    12 bar(174 psi)/20°C(68°F)
    8 bar(116 psi)/125°C(257°F)

Field of application

The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.

 

Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:

  • Phase separation of product/water and product/product mixtures in pipe systems

  • Control of CIP (cleaning in place) processes in the return channel

  • Concentration control in remaking of CIP cleaning agents

  • Product monitoring in pipe systems, bottling plants, quality assurance

  • Leakage monitoring

Its unique hygienic design is certified by EHEDG and 3-A.

Benefits

  • Unique hygienic design avoids contamination

  • With all hygienic certificates required in hygienic applications

  • Food grade virgin PEEK body without joints nor crevices

  • Certified biocompatibility according to USP class VI

  • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)

  • Compliant with EG 2023/2006 and 1935/2004

products
PRODUCTS DETAILS
Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022
MOQ: 1pcs
Price: Negotiable
Standard Packaging: Original packing
Delivery Period: On request
Payment Method: T/T
Supply Capacity: 5000pcs/month
Detail Information
Place of Origin
DE
Brand Name
Endress Hauser
Certification
Rohs
Model Number
CLS54-AAA5022
Measurement Range:
100 µS/cm - 2000 MS/cm Cell Constant K: 6,3 1/cm
Process Temperature:
-10°C - +125°C
Sterilisation:
150°C/5 Bar (max. 60 Min.)
Process Pressure:
12 Bar(174 Psi)/20°C(68°F)
Measuring Principle:
Inductive Conductivity Measurement
Minimum Order Quantity:
1pcs
Price:
Negotiable
Packaging Details:
Original packing
Delivery Time:
On request
Payment Terms:
T/T
Supply Ability:
5000pcs/month
Highlight

Indumax analog electrical conductivity sensor

,

CLS54 analog electrical conductivity sensor

Product Description

Analog Conductivity Sensor Indumax CLS54 E&H Instrument CLS54-AAA5022

Process pressure

12 bar(174 psi)/20°C(68°F)

Ingress protection

IP68/NEMA6P

Measuring principle

Inductive conductivity measurement

 

Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022 0Indumax CLS54 Analog Electrical Conductivity Sensor E&H Instrument CLS54-AAA5022 1

 

Specs at a glance

  • Measurement range

    100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm

  • Process temperature

    Process temperature: -10°C - +125°C
    (14°F - 257°F)
    Sterilisation: 150°C/5 bar (max. 60 min.)
    (302°F / 72.5 psi)

  • Process pressure

    12 bar(174 psi)/20°C(68°F)
    8 bar(116 psi)/125°C(257°F)

Field of application

The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.

 

Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:

  • Phase separation of product/water and product/product mixtures in pipe systems

  • Control of CIP (cleaning in place) processes in the return channel

  • Concentration control in remaking of CIP cleaning agents

  • Product monitoring in pipe systems, bottling plants, quality assurance

  • Leakage monitoring

Its unique hygienic design is certified by EHEDG and 3-A.

Benefits

  • Unique hygienic design avoids contamination

  • With all hygienic certificates required in hygienic applications

  • Food grade virgin PEEK body without joints nor crevices

  • Certified biocompatibility according to USP class VI

  • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)

  • Compliant with EG 2023/2006 and 1935/2004

Sitemap |  Privacy Policy | China Good Quality Emerson Rosemount Pressure Transmitter Supplier. Copyright © 2021-2025 GREAT SYSTEM INDUSTRY CO. LTD . All Rights Reserved.