Teledyne Oxygen sensor B74033-A2CXL for general purpose trace oxygen analysis
Used for trace Oxygen (O2) measurements in Carbon Dioxide (CO2) containing backgrounds (0.1-100% CO2). CO2 must be present
A-1: Obsolete, contact factory | |||
A-2C oxygen sensor |
C6689-A2C | Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
A-2CXL oxygen sensor |
B74033-A2CXL | Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
A-2Cl: Obsolete, use A-2C | |||
A-3: Obsolete, use A-5 | |||
A-5 oxygen sensor |
C6689-A5 | Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. | Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration. |
B-1 oxygen sensor |
C6689-B1 | General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). | Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas. |
B-2C oxygen sensor |
C6689-B2C | General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. |
INSTA TRACE oxygen sensor |
B71875 | Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. | Used for trace O2 analysis in inert gas and hydrocarbon streams. |
B-2CXL oxygen sensor |
C6689-B2CXL | Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. |
B-3 oxygen sensor |
C6689-B3 | Percent O2 analysis, best compromise between long life and fast response. | May be used to spot check flue gas. |
B-4C oxygen sensor |
C14613-B4C | Trace O2 cell specifically designed for the Model 317EXI. | Same performance as the B-2. |
B-5 oxygen sensor |
C45091-B5 | Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. | Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air. |
B-5F oxygen sensor |
C45091-B5F | Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. | Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months. |
B-7 oxygen sensor |
C45091-B7 | Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. | Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months. |
B-7F oxygen sensor |
C45091-B7F | Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. | Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months. |
C-1 oxygen sensor |
C6689-C1 | Rarely used. Schematic for reference only. | |
C-2 oxygen sensor |
C6689-C2 | Rarely used. Schematic for reference only. | |
C-3 oxygen sensor |
C6689-C3 | Percent O2 measurements where maximum cell life is desired (high O2 applications). | 90% response time is 30 seconds. Expected life in air is 18 months. |
C-5 oxygen sensor |
C45091-C5 | Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. | Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months. |
C-5F oxygen sensor |
C45091-C5F | Special application cell (non-standard) where long life, in the presence of CO2, is required. | Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months. |
C-6 oxygen sensor |
C54090-C6 | Motion insensitive percent O2 measurements for use in hand held portable monitors. | Best cell for OEM safety applications. |
E-1 oxygen sensor |
C14991-E1 | Special cell with performance characteristic of the C-3 with 5x the life. | Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators. |
E-2 oxygen sensor |
C57283-E2 | Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). | Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm. |
F-1R | C40371-F1R | 0-1000 ppm CO in Air | Used in Max 5 and 9950 Portable Combustion Analyzers |
Common Models:
3000MA
3010MA
3110(311D)
311TC
3000TA
311
311XL
311TCXL
311PC
3190
320P
3010PAC
4020
8800A
INSTATRANS 3001
INSTATRANS-XD
3290
A-2C
L-2C
B-2CXL
A-5
B-2C
B-37937
UFO-130-2
C73870
C65098A
D67472REV8
GB300
INSTA TRACE (B71875)
R-22A
Why choose GSI?
1. 100% original product, 100% quality assurance.
2. Varied payment methods.
We adopt T/T, western union and paypal and Currency in EURO,USD,RMB
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.
Contact Person: Mrs. Joanna Yang
Tel: +86-13828861501
Fax: 86-755-26850713