Number of channels:One
Location of switch:
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
The MTL5514-T enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
Number of channels | One |
Location of switch | Zone 0, IIC, T6 hazardous area |
Div.1, Group A, hazardous location | |
Location of proximity detector | |
Zone 0, IIC, T4–6 hazardous area, if suitably certified | |
Div.1, Group A, hazardous location | |
Hazardous–area inputs | Inputs conforming to BS EN60947–5–6:2001 standards for |
proximity detectors (NAMUR) | |
Voltage applied to sensor | 7 to 9V dc from 1kΩ ±10% |
Input/output characteristics | Normal phase |
Outputs closed if input > 2.1mA (< 2kΩ in input circuit) | |
Outputs open if input < 1.2mA (> 10kΩ in input circuit) | |
Hysteresis: 200µA (650Ω) nominal | |
Line fault detection (LFD) (when selected) | |
User-selectable via switches on the side of the unit. Line faults | |
are indicated by an LED. Line fault relay is energised and channel | |
output relay de-energised if input line-fault detected | |
Open-circuit alarm on if Iin < 50µA | |
Open-circuit alarm off if Iin > 250µA | |
Short-circuit alarm on if Rin < 100Ω | |
Short-circuit alarm off if Rin > 360Ω | |
Note: Resistors must be fitted when using the LFD facility with a contact input | |
500Ω to 1kΩ in series with switch | |
20kΩ to 25kΩ in parallel with switch | |
Safe-area output | |
Channel: Single pole relay with changeover contacts | |
LFD: Single pole relay with changeover contacts | |
Note: reactive loads must be adequately suppressed |
·1-channel,
·line fault detection,
·phase reversal
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with us.
MOQ: | 1 |
Price: | Negotiable |
Standard Packaging: | carton |
Delivery Period: | on request |
Payment Method: | T/T |
Supply Capacity: | 100+pc+on stock |
Number of channels:One
Location of switch:
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
The MTL5514-T enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
Number of channels | One |
Location of switch | Zone 0, IIC, T6 hazardous area |
Div.1, Group A, hazardous location | |
Location of proximity detector | |
Zone 0, IIC, T4–6 hazardous area, if suitably certified | |
Div.1, Group A, hazardous location | |
Hazardous–area inputs | Inputs conforming to BS EN60947–5–6:2001 standards for |
proximity detectors (NAMUR) | |
Voltage applied to sensor | 7 to 9V dc from 1kΩ ±10% |
Input/output characteristics | Normal phase |
Outputs closed if input > 2.1mA (< 2kΩ in input circuit) | |
Outputs open if input < 1.2mA (> 10kΩ in input circuit) | |
Hysteresis: 200µA (650Ω) nominal | |
Line fault detection (LFD) (when selected) | |
User-selectable via switches on the side of the unit. Line faults | |
are indicated by an LED. Line fault relay is energised and channel | |
output relay de-energised if input line-fault detected | |
Open-circuit alarm on if Iin < 50µA | |
Open-circuit alarm off if Iin > 250µA | |
Short-circuit alarm on if Rin < 100Ω | |
Short-circuit alarm off if Rin > 360Ω | |
Note: Resistors must be fitted when using the LFD facility with a contact input | |
500Ω to 1kΩ in series with switch | |
20kΩ to 25kΩ in parallel with switch | |
Safe-area output | |
Channel: Single pole relay with changeover contacts | |
LFD: Single pole relay with changeover contacts | |
Note: reactive loads must be adequately suppressed |
·1-channel,
·line fault detection,
·phase reversal
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with us.