MOQ: | 1 |
Price: | negotiable |
Standard Packaging: | standard carton packing |
Delivery Period: | on request |
Payment Method: | T/T |
Supply Capacity: | 0-1000pcs |
CM42 MEA000EAZ00 E&H 1 Channel Transmitter Liquiline M CM42
CM42-MEA000EAZ00 1-Channel Transmitter Liquiline M CM42
Model:CM42-MEA000EAZ00
Sensor Input: M Digital, Memosens pH, (glass) ORP
Approval: E ATEX II (1)2G Ex ib (ia Ga) IIC T4/T6 G
Certificate: A not selected
Output: 0 1x4-20mA, HART
Housing: 0 Plastics (PC)
Cable Entry: 0 Gland M20x1,5
Software: EA Basic version
Language Instrument: Documentation: Z Chinese + English; Chinese
Documentation: 0 Starting up + operation
Additional option: 0 Basic version
HS-Code: 90278930
Country of origin: DE
Country of dispatch: DE
Two-wire field device for hazardous and non-hazardous area use in chemicals, life sciences and food
Specs at a glance
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
Ingres protection
IP66/67, NEMA 4X
Field of application
Liquiline M CM42 is the robust transmitter for pH/ORP, conductivity or oxygen measurement in all process applications. It is the best choice for demanding environments be it hygienic applications, hazardous areas or functional safety areas. Liquiline’s intuitive operating concept simplifies commissioning, handling, and maintenance saving you time every day. Easy switching of parameters and seamless system integration give you the flexibility to adapt it exactly to your measuring task.
The Liquiline CM42 transmitter is suitable for all process applications, for example in these industries and their utilities:
Liquiline CM42 features the following protocols and interfaces:
With its international explosion protection approvals, such as IECEx, ATEX, FM, CSA, TIIS and NEPSI, the transmitter is suitable for hazardous area use.
Benefits
Common related models:
CUS52D-AA1AA3 |
CPS72-0PT2ESA |
FMP57-AAACCALCA4GGE+LA |
CLS16-3D3A1P |
FHX50-AACDBA |
FMR50-AACLAABMGGF+AK |
FDU93-RG2A |
FMU90-R11CA111AA3A |
FTL325N-H1E1 |
CLS21D-C1N1 |
8E1C08-AADBBAASAD2SHA1+AK |
DTI200-A13C2A |
5H2B02-AAACCAAD5S0A+AK |
CM42-IIA000EAZ00 |
FTL33-AA4U3ABWSJ |
FMR60-AAACCAGAA4GGJ+AK |
FMR52-BCKCCDBPAJK+AKZ1 |
52006326 |
CPF81-LH31C4 |
5P5B65-4290/0 |
Why choose GSI?
1. 100% original product, 100% quality assurance.
2. Varied payment methods.
We adopt T/T, western union and paypal and Currency in EURO,USD,RMB
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.
MOQ: | 1 |
Price: | negotiable |
Standard Packaging: | standard carton packing |
Delivery Period: | on request |
Payment Method: | T/T |
Supply Capacity: | 0-1000pcs |
CM42 MEA000EAZ00 E&H 1 Channel Transmitter Liquiline M CM42
CM42-MEA000EAZ00 1-Channel Transmitter Liquiline M CM42
Model:CM42-MEA000EAZ00
Sensor Input: M Digital, Memosens pH, (glass) ORP
Approval: E ATEX II (1)2G Ex ib (ia Ga) IIC T4/T6 G
Certificate: A not selected
Output: 0 1x4-20mA, HART
Housing: 0 Plastics (PC)
Cable Entry: 0 Gland M20x1,5
Software: EA Basic version
Language Instrument: Documentation: Z Chinese + English; Chinese
Documentation: 0 Starting up + operation
Additional option: 0 Basic version
HS-Code: 90278930
Country of origin: DE
Country of dispatch: DE
Two-wire field device for hazardous and non-hazardous area use in chemicals, life sciences and food
Specs at a glance
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
Ingres protection
IP66/67, NEMA 4X
Field of application
Liquiline M CM42 is the robust transmitter for pH/ORP, conductivity or oxygen measurement in all process applications. It is the best choice for demanding environments be it hygienic applications, hazardous areas or functional safety areas. Liquiline’s intuitive operating concept simplifies commissioning, handling, and maintenance saving you time every day. Easy switching of parameters and seamless system integration give you the flexibility to adapt it exactly to your measuring task.
The Liquiline CM42 transmitter is suitable for all process applications, for example in these industries and their utilities:
Liquiline CM42 features the following protocols and interfaces:
With its international explosion protection approvals, such as IECEx, ATEX, FM, CSA, TIIS and NEPSI, the transmitter is suitable for hazardous area use.
Benefits
Common related models:
CUS52D-AA1AA3 |
CPS72-0PT2ESA |
FMP57-AAACCALCA4GGE+LA |
CLS16-3D3A1P |
FHX50-AACDBA |
FMR50-AACLAABMGGF+AK |
FDU93-RG2A |
FMU90-R11CA111AA3A |
FTL325N-H1E1 |
CLS21D-C1N1 |
8E1C08-AADBBAASAD2SHA1+AK |
DTI200-A13C2A |
5H2B02-AAACCAAD5S0A+AK |
CM42-IIA000EAZ00 |
FTL33-AA4U3ABWSJ |
FMR60-AAACCAGAA4GGJ+AK |
FMR52-BCKCCDBPAJK+AKZ1 |
52006326 |
CPF81-LH31C4 |
5P5B65-4290/0 |
Why choose GSI?
1. 100% original product, 100% quality assurance.
2. Varied payment methods.
We adopt T/T, western union and paypal and Currency in EURO,USD,RMB
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.