Send Message
products
PRODUCTS DETAILS
Home > Products >
FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50

FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50

MOQ: 1
Price: negotiable
Standard Packaging: standard carton packing
Delivery Period: on request
Payment Method: T/T
Supply Capacity: 0-1000pcs
Detail Information
Place of Origin
Germany
Brand Name
E&H
Certification
Rohs
Model Number
FTL50-1DN80/0
Approval:
Non-hazardous Area
Process Connectio::
NPS 1-1/4" Cl.150 RF, 316/316L Flange ASME B16.5
Probe Length; Type:
Compact; Ra<3.2um/126uin
Electronics; Output:
**FEL54;SILrelay DPDT 19-253VAC/19-55VDC
Housing; Cable Entry:
**F16 IP66/67 Polyester; M20 Gland
Additional Option:
Basic Version
Highlight:

Polyester Liquiphant FTL50

,

Non Hazardous Area Liquiphant FTL50

,

IP66 Vibronic Point Level Detection

Product Description

FTL50-1DN80/0 FTL50-AAA2AA4G4A+L8 Vibronik Grenzstanddetektion Liquiphant FTL50

Approval:  A  Non-hazardous area
Process Connection:  AA2  NPS 1-1/4" Cl.150 RF, 316/316L flange ASME B16.5
Probe Length; Type:  AA  Compact; Ra<3.2um/126uin
Electronics; Output:  4  **FEL54;SILrelay DPDT 19-253VAC/19-55VDC
Housing; Cable Entry:  G4  **F16 IP66/67 Polyester; M20 gland
Additional Option:  A  Basic version
>>Additional Approval:  L8  EAC marking

 

Specs at a glance
Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F)
Process pressure / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi)
Min. density of medium
0.5g/cm³(0.4g/cm³ option)

 

Field of application
Liquiphant FTL50 is a point level switch for use in hazardous areas with all international certificates. Useable in all industries. FTL50 offers functional safety SIL2/SIL3. With the second line of defense the highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.


Point level switch for all liquids.

  • Process connections: Threads, flanges and hygienic process connection (Tri-Clamp)
  • Temperature: -50 to +150°C (-58 to +302°F)
  • Pressure: -1 to +64bar (-14.5 to +928psi)
  • Sensor material: 316L, Alloy
  • International explosion protection certificates, overfill prevention WHG, SIL, marine approvals

Benefits

  • Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
  • International explosion protection certificates and overfill prevention certificate (WHG)
  • No calibration required, easy to start up
  • No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function
  • Second line of defense to protect the environment
  • Variety of standardized process connections for all applications
  • Stainless steel (316L) and high-corrosion resistant sensor material (Alloy)

FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 0  FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 1  FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 2

 

Common related models:

FTL31-AA4U2BAWBJ
FTM21-AA245A,L=500mm
FTL31-AA4U3BAWSJ
FTL31-AA4U2AAWBJ
CPM223-MR8005
CPS16D-7AT2G
CLS21-C1N3A
FTL33-AA4N3AB1GJ+RM
FTL31-AA4M3AAWBJ+HD
5H3B04-AAIBAEAFAAAO2V0AA1+AK
FMX21-AA111HGB10A+PQ,L=10m
FTL325N-F1A1
FTL50-ABG2AA4E7A
RIA14-BD3B+I4Z1
CLS50-A2B2


Frequently Asked Questions:

Q: Does your goods are new and original?

A: Yes, they are new and original.

 

Q: How long warranty?

A: One-year warranty.

 

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with us.

 

 

 

 

products
PRODUCTS DETAILS
FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50
MOQ: 1
Price: negotiable
Standard Packaging: standard carton packing
Delivery Period: on request
Payment Method: T/T
Supply Capacity: 0-1000pcs
Detail Information
Place of Origin
Germany
Brand Name
E&H
Certification
Rohs
Model Number
FTL50-1DN80/0
Approval:
Non-hazardous Area
Process Connectio::
NPS 1-1/4" Cl.150 RF, 316/316L Flange ASME B16.5
Probe Length; Type:
Compact; Ra<3.2um/126uin
Electronics; Output:
**FEL54;SILrelay DPDT 19-253VAC/19-55VDC
Housing; Cable Entry:
**F16 IP66/67 Polyester; M20 Gland
Additional Option:
Basic Version
Minimum Order Quantity:
1
Price:
negotiable
Packaging Details:
standard carton packing
Delivery Time:
on request
Payment Terms:
T/T
Supply Ability:
0-1000pcs
Highlight

Polyester Liquiphant FTL50

,

Non Hazardous Area Liquiphant FTL50

,

IP66 Vibronic Point Level Detection

Product Description

FTL50-1DN80/0 FTL50-AAA2AA4G4A+L8 Vibronik Grenzstanddetektion Liquiphant FTL50

Approval:  A  Non-hazardous area
Process Connection:  AA2  NPS 1-1/4" Cl.150 RF, 316/316L flange ASME B16.5
Probe Length; Type:  AA  Compact; Ra<3.2um/126uin
Electronics; Output:  4  **FEL54;SILrelay DPDT 19-253VAC/19-55VDC
Housing; Cable Entry:  G4  **F16 IP66/67 Polyester; M20 gland
Additional Option:  A  Basic version
>>Additional Approval:  L8  EAC marking

 

Specs at a glance
Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F)
Process pressure / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi)
Min. density of medium
0.5g/cm³(0.4g/cm³ option)

 

Field of application
Liquiphant FTL50 is a point level switch for use in hazardous areas with all international certificates. Useable in all industries. FTL50 offers functional safety SIL2/SIL3. With the second line of defense the highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.


Point level switch for all liquids.

  • Process connections: Threads, flanges and hygienic process connection (Tri-Clamp)
  • Temperature: -50 to +150°C (-58 to +302°F)
  • Pressure: -1 to +64bar (-14.5 to +928psi)
  • Sensor material: 316L, Alloy
  • International explosion protection certificates, overfill prevention WHG, SIL, marine approvals

Benefits

  • Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
  • International explosion protection certificates and overfill prevention certificate (WHG)
  • No calibration required, easy to start up
  • No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function
  • Second line of defense to protect the environment
  • Variety of standardized process connections for all applications
  • Stainless steel (316L) and high-corrosion resistant sensor material (Alloy)

FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 0  FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 1  FTL50-1DN80/0 Vibronic Point Level Detection , IP66 Liquiphant FTL50 2

 

Common related models:

FTL31-AA4U2BAWBJ
FTM21-AA245A,L=500mm
FTL31-AA4U3BAWSJ
FTL31-AA4U2AAWBJ
CPM223-MR8005
CPS16D-7AT2G
CLS21-C1N3A
FTL33-AA4N3AB1GJ+RM
FTL31-AA4M3AAWBJ+HD
5H3B04-AAIBAEAFAAAO2V0AA1+AK
FMX21-AA111HGB10A+PQ,L=10m
FTL325N-F1A1
FTL50-ABG2AA4E7A
RIA14-BD3B+I4Z1
CLS50-A2B2


Frequently Asked Questions:

Q: Does your goods are new and original?

A: Yes, they are new and original.

 

Q: How long warranty?

A: One-year warranty.

 

Q: Does any certificates can be provided?

A: Yes, it depends on what product you request, please check details with us.

 

 

 

 

Sitemap |  Privacy Policy | China Good Quality Emerson Rosemount Pressure Transmitter Supplier. Copyright © 2021-2025 GREAT SYSTEM INDUSTRY CO. LTD . All Rights Reserved.