Place of Origin
DE
Brand Name
Endress Hauser
Certification
Rohs
Model Number
8I3B50-1UA1/0
Measuring Range:
0 To 180 000 Kg/h (0 To 6600 Lb/min)
Medium Temperature Range:
–50 To +150 °C (–58 To +302 °F)
Max. Process Pressure:
PN 100, Class 600, 63K
Measuring Tube:
Titanium Grade 9
Connection:
Titanium Grade 2
Measuring Principle:
Coriolis
Highlight:

Promass I 300 Coriolis Flowmeter

,

Straight Single Tube Coriolis Flowmeter

,

PN 100 Coriolis Flow Meter

Product Description

Proline Promass I 300 Coriolis flowmeter 8I3B50-1UA1/0

 

Measuring tube Titanium grade 9
Connection Titanium grade 2

Max. process pressure

PN 100, Class 600, 63K

 

Proline Promass I 300 Coriolis Flowmeter straight single tube design 8I3B50-1UA1/0 0Proline Promass I 300 Coriolis Flowmeter straight single tube design 8I3B50-1UA1/0 1

  • Measuring principle

    Coriolis

  • Product headline

    Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
    .
    Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

  • Sensor features

    Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

    DN 8 to 80 (⅜ to 3")

  • Wetted materials

    Measuring tube: Titanium grade 9
    Connection: Titanium grade 2

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 180 000 kg/h (0 to 6600 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301/1.4307 (304L), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

  • Degree of protection

    IP66/67, type 4X enclosure
    IP69

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

     

    Specs at a glance

    • Max. measurement error

      Mass flow (liquid): ±0.10 %
      Volume flow (liquid): ±0.10 %
      Mass flow (gas): ±0.50 %
      Density (liquid): ±0.0005 g/cm³

    • Measuring range

      0 to 180 000 kg/h (0 to 6600 lb/min)

    • Medium temperature range

      –50 to +150 °C (–58 to +302 °F)

    • Max. process pressure

      PN 100, Class 600, 63K

    • Wetted materials

      Measuring tube: Titanium grade 9
      Connection: Titanium grade 2

    Field of application

    The straight single-tube design of Promass I provides in-line viscosity measurement in addition to mass flow, density and temperature measurement. With its compact transmitter Promass I 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.

     
    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

    Device properties

    • Straight, easy-to-clean single-tube system

    • TMB technology

    • Measuring tube made of Titanium

    • Compact dual-compartment housing with up to 3 I/Os

    • Backlit display with touch control and WLAN access

    • Remote display available

    Benefits

    • Energy-saving – full bore design enables minimal pressure loss

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses

    • Reduced complexity and variety – freely configurable I/O functionality

    • Integrated verification – Heartbeat Technology

    3-A, EHEDG, cGMP

     

     

products
PRODUCTS DETAILS
Proline Promass I 300 Coriolis Flowmeter straight single tube design 8I3B50-1UA1/0
MOQ: 1pcs
Price: Negotiable
Standard Packaging: Original packing
Delivery Period: On request
Payment Method: T/T
Supply Capacity: 5000pcs/month
Detail Information
Place of Origin
DE
Brand Name
Endress Hauser
Certification
Rohs
Model Number
8I3B50-1UA1/0
Measuring Range:
0 To 180 000 Kg/h (0 To 6600 Lb/min)
Medium Temperature Range:
–50 To +150 °C (–58 To +302 °F)
Max. Process Pressure:
PN 100, Class 600, 63K
Measuring Tube:
Titanium Grade 9
Connection:
Titanium Grade 2
Measuring Principle:
Coriolis
Minimum Order Quantity:
1pcs
Price:
Negotiable
Packaging Details:
Original packing
Delivery Time:
On request
Payment Terms:
T/T
Supply Ability:
5000pcs/month
Highlight

Promass I 300 Coriolis Flowmeter

,

Straight Single Tube Coriolis Flowmeter

,

PN 100 Coriolis Flow Meter

Product Description

Proline Promass I 300 Coriolis flowmeter 8I3B50-1UA1/0

 

Measuring tube Titanium grade 9
Connection Titanium grade 2

Max. process pressure

PN 100, Class 600, 63K

 

Proline Promass I 300 Coriolis Flowmeter straight single tube design 8I3B50-1UA1/0 0Proline Promass I 300 Coriolis Flowmeter straight single tube design 8I3B50-1UA1/0 1

  • Measuring principle

    Coriolis

  • Product headline

    Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
    .
    Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

  • Sensor features

    Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

    DN 8 to 80 (⅜ to 3")

  • Wetted materials

    Measuring tube: Titanium grade 9
    Connection: Titanium grade 2

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 180 000 kg/h (0 to 6600 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301/1.4307 (304L), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

  • Degree of protection

    IP66/67, type 4X enclosure
    IP69

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

     

    Specs at a glance

    • Max. measurement error

      Mass flow (liquid): ±0.10 %
      Volume flow (liquid): ±0.10 %
      Mass flow (gas): ±0.50 %
      Density (liquid): ±0.0005 g/cm³

    • Measuring range

      0 to 180 000 kg/h (0 to 6600 lb/min)

    • Medium temperature range

      –50 to +150 °C (–58 to +302 °F)

    • Max. process pressure

      PN 100, Class 600, 63K

    • Wetted materials

      Measuring tube: Titanium grade 9
      Connection: Titanium grade 2

    Field of application

    The straight single-tube design of Promass I provides in-line viscosity measurement in addition to mass flow, density and temperature measurement. With its compact transmitter Promass I 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.

     
    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

    Device properties

    • Straight, easy-to-clean single-tube system

    • TMB technology

    • Measuring tube made of Titanium

    • Compact dual-compartment housing with up to 3 I/Os

    • Backlit display with touch control and WLAN access

    • Remote display available

    Benefits

    • Energy-saving – full bore design enables minimal pressure loss

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses

    • Reduced complexity and variety – freely configurable I/O functionality

    • Integrated verification – Heartbeat Technology

    3-A, EHEDG, cGMP

     

     

Sitemap |  Privacy Policy | China Good Quality Emerson Rosemount Pressure Transmitter Supplier. Copyright © 2021-2025 GREAT SYSTEM INDUSTRY CO. LTD . All Rights Reserved.