Send Message
Great System International Limited

Great System International Limited

Home ProductsE&H Instrument

Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1

Certification
China Great System International Limited certification
Hello Qiang. Happy New 2021 Year! We start working Year from today. Thank you very much for cooperation in the last year and hope we will do it better this year!

—— Alexandr Blagov

Frank, Thank you for your honesty and your company trusty last year I hope will be extend our business together next year.Have a good holiday.

—— Hbabaee

It has been very nice to cooperate with you through all these years and thank you so much for your kind support and best service!

—— Niloufar Soltani

I'm Online Chat Now

Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1

Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1
Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1 Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1 Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1 Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1

Large Image :  Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1

Product Details:
Place of Origin: DE
Brand Name: Endress Hauser
Certification: Rohs
Model Number: 5H3B65-AAIBAEAFAAFDASGAA1
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: Negotiable
Packaging Details: Original packing
Delivery Time: On request
Payment Terms: T/T
Supply Ability: 5000pcs/month
Detailed Product Description
Volume Flow (standard): ±0.5 % O.r.± 1 Mm/s (0.04 In/s) Measuring Range: 0.06 Dm³/min To 600 M³/h (0.015 Gal/min To 2 650 Gal/min)
Medium Temperature Range: –20 To +150 °C (–4 To +302 °F) Max. Process Pressure: PN 40, Class 150, 20K
Measuring Principle: Electromagnetic Nominal Diameter Range: DN 2 To 150 (¹⁄₁₂ To 6")
High Light:

rohs e&h mag flow meter

,

picomag e&h mag flow meter

,

h 300 picomag flow meter

Proline Promag H 300 electromagnetic flowmeter 5H3B65-AAIBAEAFAAFDASGAA1

Max. process pressure

PN 40, Class 150, 20K

Medium temperature range

–20 to +150 °C (–4 to +302 °F)

Sensor housing material

1.4301 (304), corrosion resistant

 

Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1 0Proline Promag H 300 E&H Mag Flow Meter 5H3B65-AAIBAEAFAAFDASGAA1 1

 

Specs at a glance

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)

  • Medium temperature range

    –20 to +150 °C (–4 to +302 °F)

  • Max. process pressure

    PN 40, Class 150, 20K

  • Wetted materials

    Liner: PFA
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
    Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
    Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
    Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum

Field of application

Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. With its compact transmitter Promag H 300 offers a high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.

 
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

  • Dedicated to demanding applications in the food and beverage as well as in life sciences industries

Device properties

  • Liner made of PFA

  • Sensor housing made of stainless steel (3A, EHEDG)

  • Wetted materials CIP, SIP cleanable

  • Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os

  • Backlit display with touch control and WLAN access

  • Remote display available

Benefits

  • Flexible installation concept – numerous hygienic process connections

  • Energy-saving flow measurement – no pressure loss due to cross-section constriction

  • Maintenance-free – no moving parts

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses

  • Reduced complexity and variety – freely configurable I/O functionality

  • Integrated verification – Heartbeat Technology