| MOQ: | 1pcs |
| Price: | Negotiable |
| Standard Packaging: | Original packing |
| Delivery Period: | On request |
| Payment Method: | T/T |
| Supply Capacity: | 50pcs/month |
| Parameter | Specification |
|---|---|
| Electrical | |
| Sensitivity | 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration. |
| Calibration Load | 10 kΩ Terminal "A" to "B" Output taken across pins "A" and "B" |
| Sensitivity Temperature Coefficient | 0.2%/°C |
| Frequency Response | 4.5 to 1000 Hz (270 to 60,000 CPM); +0, -3dB typical. 10 to 1000 Hz (600 to 60,000 CPM); +0, -3dB typical. 15 to 1000 Hz (900 to 60,000 CPM); +0, -3dB typical. |
| Dynamic Operating Range | 2.54 mm (0.100 in) peak to peak maximum displacement. |
| Velocity Range | 25 mm/s (1 in/s) (at +22 °C of casing vibration at 100 Hz with a 10 kΩ load. |
| Coil Resistance | 1.25 kΩ ±5% |
| Locked Coil Inductance | 125 mH, typical |
| Amplitude Linearity | ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000CPM) |
| Shock Resistance | Withstands 50 g peak maximum acceleration along non-sensitive axis. |
| Transverse Sensitivity | ±10% maximum of the sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s) |
| Polarity of Output Signal | Pin A goes positive with respect to Pin B when the transducer case velocity is towards the connector. |
| Lead Wire Length | 305 meters (1,000 feet) maximum between Seismoprobe Velocity Transducer and 3300 or Bently Nevada™ 3500 Monitor. Consult manual for frequency roll-off at longer lengths. |
| Parameter | Specification |
|---|---|
| Operating and Storage Temperature | 9200: -29°C to +121°C (-20°F to +250°F) 74712: -29°C to +204°C (-20°F to +400°F) |
| Environment | Dust and moisture resistant. Contact your Sales Professional regarding transducer operation in a radiation environment. |
| Relative Humidity | To 95%, noncondensing. 100%, non-submerged, when ordered with integral cable. |
| Maximum Use Altitude | 2000 m (6,561 ft) above sea level. |
| Option | Description |
|---|---|
| A: Transducer Mounting Angle/Minimum Operating Frequency Option |
01: 0 ±2.5, 4.5 Hz (270 cpm) 02: 45 ±2.5, 4.5 Hz (270 cpm) 03: 90 ±2.5, 4.5 Hz (270 cpm) 06: 0 ±100, 10 Hz (600 cpm) 09: 0 ±180, 15 Hz (900 cpm) |
| B: Connector/Cable Option |
01: Top Mount (no cable) 02: Side Mount (no cable) 05: Terminal block top mount (no cable) 10 through 50: Integral hardline cable Standard cable lengths: 10: 10 feet (3.0 meter) 15: 15 feet (4.6 meter) 22: 22 feet (6.7 meter) 32: 32 feet (9.8 meter) 50: 50 feet (15.2 meter) Other cable lengths between 7 feet and 50 feet may be available through custom products. |
| C: Mounting Base Option |
01: Circular; 1/4-20 UNC stud 02: Circular; 1/4-28 UNF stud 03: Rectangular flange 04: Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle 05: No base; 1/2-20 UNF-3A stud 06: Isolated circular 1/4-20 UNC stud 07: Isolated circular 1/4-28 UNF stud 08: Isolated rectangular flange 09: Isolated circular 5/8-18 UNF stud 10: Circular; M10X1 stud 11: Isolated circular M10X1 12: Isolated circular 1/2-20 UNF-2A |
| D: Agency Approval Option |
00: No Approvals 01: CSA 04: ATEX/IECEx |
| MOQ: | 1pcs |
| Price: | Negotiable |
| Standard Packaging: | Original packing |
| Delivery Period: | On request |
| Payment Method: | T/T |
| Supply Capacity: | 50pcs/month |
| Parameter | Specification |
|---|---|
| Electrical | |
| Sensitivity | 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration. |
| Calibration Load | 10 kΩ Terminal "A" to "B" Output taken across pins "A" and "B" |
| Sensitivity Temperature Coefficient | 0.2%/°C |
| Frequency Response | 4.5 to 1000 Hz (270 to 60,000 CPM); +0, -3dB typical. 10 to 1000 Hz (600 to 60,000 CPM); +0, -3dB typical. 15 to 1000 Hz (900 to 60,000 CPM); +0, -3dB typical. |
| Dynamic Operating Range | 2.54 mm (0.100 in) peak to peak maximum displacement. |
| Velocity Range | 25 mm/s (1 in/s) (at +22 °C of casing vibration at 100 Hz with a 10 kΩ load. |
| Coil Resistance | 1.25 kΩ ±5% |
| Locked Coil Inductance | 125 mH, typical |
| Amplitude Linearity | ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000CPM) |
| Shock Resistance | Withstands 50 g peak maximum acceleration along non-sensitive axis. |
| Transverse Sensitivity | ±10% maximum of the sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s) |
| Polarity of Output Signal | Pin A goes positive with respect to Pin B when the transducer case velocity is towards the connector. |
| Lead Wire Length | 305 meters (1,000 feet) maximum between Seismoprobe Velocity Transducer and 3300 or Bently Nevada™ 3500 Monitor. Consult manual for frequency roll-off at longer lengths. |
| Parameter | Specification |
|---|---|
| Operating and Storage Temperature | 9200: -29°C to +121°C (-20°F to +250°F) 74712: -29°C to +204°C (-20°F to +400°F) |
| Environment | Dust and moisture resistant. Contact your Sales Professional regarding transducer operation in a radiation environment. |
| Relative Humidity | To 95%, noncondensing. 100%, non-submerged, when ordered with integral cable. |
| Maximum Use Altitude | 2000 m (6,561 ft) above sea level. |
| Option | Description |
|---|---|
| A: Transducer Mounting Angle/Minimum Operating Frequency Option |
01: 0 ±2.5, 4.5 Hz (270 cpm) 02: 45 ±2.5, 4.5 Hz (270 cpm) 03: 90 ±2.5, 4.5 Hz (270 cpm) 06: 0 ±100, 10 Hz (600 cpm) 09: 0 ±180, 15 Hz (900 cpm) |
| B: Connector/Cable Option |
01: Top Mount (no cable) 02: Side Mount (no cable) 05: Terminal block top mount (no cable) 10 through 50: Integral hardline cable Standard cable lengths: 10: 10 feet (3.0 meter) 15: 15 feet (4.6 meter) 22: 22 feet (6.7 meter) 32: 32 feet (9.8 meter) 50: 50 feet (15.2 meter) Other cable lengths between 7 feet and 50 feet may be available through custom products. |
| C: Mounting Base Option |
01: Circular; 1/4-20 UNC stud 02: Circular; 1/4-28 UNF stud 03: Rectangular flange 04: Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle 05: No base; 1/2-20 UNF-3A stud 06: Isolated circular 1/4-20 UNC stud 07: Isolated circular 1/4-28 UNF stud 08: Isolated rectangular flange 09: Isolated circular 5/8-18 UNF stud 10: Circular; M10X1 stud 11: Isolated circular M10X1 12: Isolated circular 1/2-20 UNF-2A |
| D: Agency Approval Option |
00: No Approvals 01: CSA 04: ATEX/IECEx |