logo
Products
PRODUCTS DETAILS
Home > Products >
YTA70-J/KS2 Yokogawa YTA70 Head Mount Temperature Transmitter HART 4-20mA Output with DIN Form B Mounting

YTA70-J/KS2 Yokogawa YTA70 Head Mount Temperature Transmitter HART 4-20mA Output with DIN Form B Mounting

MOQ: 1
Price: Negotiate
Standard Packaging: carton
Delivery Period: stock
Payment Method: T/T,Alipay,Paypal
Supply Capacity: 100pcs per month
Detail Information
Place of Origin
China
Brand Name
Yokogawa
Certification
ATEX
Model Number
YTA70-J/KS2
Manufacturer:
Yokogawa
Product Type:
YTA70 Temperature Transmitter
Output:
Two Wire 4 To 20 MA DC
Input Type:
Thermocouples, 2/3/4-wire RTDs, Ohms And DC Millivolts
Communication:
HART 5 / HART 7
Mounting:
DIN Form B Head Mounting
Ambient Temperature Limits:
-40 To 85 DegC (-40 To 185 DegF)
Isolation:
Input/output Isolated To 1500 V AC
Material:
Polycarbonate
Weight:
50 G (0.11 Lb)
Highlight:

Yokogawa YTA70 temperature transmitter HART

,

YTA70-J temperature transmitter 4-20mA output

,

DIN Form B mount temperature transmitter

Product Description
YTA70-J/KS2 Yokogawa YTA70 Head Mount Temperature Transmitter HART 4-20mA Output with DIN Form B Mounting YTA70-J/KS2 Yokogawa YTA70 Temperature Transmitter

The YTA70 is a head mount type temperature transmitter that accepts thermocouple, RTD, ohms or DC millivolt input and converts it to a 4 to 20 mA DC signal for transmission. It conforms to the standard DIN form B head mounting and supports HART communication, with the protocol revision selectable between HART 5 and HART 7. HART 7 features a long tag number of up to 32 characters, enhanced burst mode, event notification and a command aggregation function.

Key Specifications
Item Specification
Manufacturer Yokogawa
Product No. YTA70-J/KS2
Product Type YTA70 Temperature Transmitter
Output Two wire 4 to 20 mA DC
Input Type Thermocouples, 2-, 3- and 4-wire RTDs, ohms and DC millivolts
Communication HART 5 / HART 7 selectable
Mounting DIN form B head mounting
Ambient Temperature Limits -40 to 85°C (-40 to 185°F)
Ambient Humidity 0% to 95% RH (non-condensation)
Isolation Input/output isolated to 1500 V AC
Cold Junction Compensation (T/C) ±1°C (±1.8°F)
Power Supply Effect ±0.005% of FS per Volt
Sensor Burnout High / Low (NAMUR NE43) or value within 3.5 to 23 mA
Response Time 1 to 60 seconds programmable
Material Polycarbonate
Color of Case Red
Terminals M3 screws
Weight 50 g (0.11 lb)
Additional Technical Details
Parameter Value
Maximum Zero Offset ±50% of selected maximum value
Input Resistance (T/C, mV) 10 MΩ, or 3 kΩ at power-off
Input Lead Wire Resistance (RTD, ohm) 5 Ω per wire or lower (up to 50 Ω per wire configurable with reduced accuracy)
EMC Conformity EN61326-1 Class A, Table 2; EN61326-2-3
EU RoHS Directive EN IEC 63000
Highlights
  • Head mount type temperature transmitter for thermocouple, RTD, ohms and DC millivolt input
  • Converts input to a two wire 4 to 20 mA DC output signal
  • Supports HART 5 or HART 7 communication, with long tag numbers up to 32 characters
  • Standard DIN form B head mounting for straightforward installation
  • Input/output isolated to 1500 V AC for reliable signal transmission

Genuine Yokogawa unit supplied with a one-year warranty. Please contact us for stock availability and bulk quotation.

Products
PRODUCTS DETAILS
YTA70-J/KS2 Yokogawa YTA70 Head Mount Temperature Transmitter HART 4-20mA Output with DIN Form B Mounting
MOQ: 1
Price: Negotiate
Standard Packaging: carton
Delivery Period: stock
Payment Method: T/T,Alipay,Paypal
Supply Capacity: 100pcs per month
Detail Information
Place of Origin
China
Brand Name
Yokogawa
Certification
ATEX
Model Number
YTA70-J/KS2
Manufacturer:
Yokogawa
Product Type:
YTA70 Temperature Transmitter
Output:
Two Wire 4 To 20 MA DC
Input Type:
Thermocouples, 2/3/4-wire RTDs, Ohms And DC Millivolts
Communication:
HART 5 / HART 7
Mounting:
DIN Form B Head Mounting
Ambient Temperature Limits:
-40 To 85 DegC (-40 To 185 DegF)
Isolation:
Input/output Isolated To 1500 V AC
Material:
Polycarbonate
Weight:
50 G (0.11 Lb)
Minimum Order Quantity:
1
Price:
Negotiate
Packaging Details:
carton
Delivery Time:
stock
Payment Terms:
T/T,Alipay,Paypal
Supply Ability:
100pcs per month
Highlight

Yokogawa YTA70 temperature transmitter HART

,

YTA70-J temperature transmitter 4-20mA output

,

DIN Form B mount temperature transmitter

Product Description
YTA70-J/KS2 Yokogawa YTA70 Head Mount Temperature Transmitter HART 4-20mA Output with DIN Form B Mounting YTA70-J/KS2 Yokogawa YTA70 Temperature Transmitter

The YTA70 is a head mount type temperature transmitter that accepts thermocouple, RTD, ohms or DC millivolt input and converts it to a 4 to 20 mA DC signal for transmission. It conforms to the standard DIN form B head mounting and supports HART communication, with the protocol revision selectable between HART 5 and HART 7. HART 7 features a long tag number of up to 32 characters, enhanced burst mode, event notification and a command aggregation function.

Key Specifications
Item Specification
Manufacturer Yokogawa
Product No. YTA70-J/KS2
Product Type YTA70 Temperature Transmitter
Output Two wire 4 to 20 mA DC
Input Type Thermocouples, 2-, 3- and 4-wire RTDs, ohms and DC millivolts
Communication HART 5 / HART 7 selectable
Mounting DIN form B head mounting
Ambient Temperature Limits -40 to 85°C (-40 to 185°F)
Ambient Humidity 0% to 95% RH (non-condensation)
Isolation Input/output isolated to 1500 V AC
Cold Junction Compensation (T/C) ±1°C (±1.8°F)
Power Supply Effect ±0.005% of FS per Volt
Sensor Burnout High / Low (NAMUR NE43) or value within 3.5 to 23 mA
Response Time 1 to 60 seconds programmable
Material Polycarbonate
Color of Case Red
Terminals M3 screws
Weight 50 g (0.11 lb)
Additional Technical Details
Parameter Value
Maximum Zero Offset ±50% of selected maximum value
Input Resistance (T/C, mV) 10 MΩ, or 3 kΩ at power-off
Input Lead Wire Resistance (RTD, ohm) 5 Ω per wire or lower (up to 50 Ω per wire configurable with reduced accuracy)
EMC Conformity EN61326-1 Class A, Table 2; EN61326-2-3
EU RoHS Directive EN IEC 63000
Highlights
  • Head mount type temperature transmitter for thermocouple, RTD, ohms and DC millivolt input
  • Converts input to a two wire 4 to 20 mA DC output signal
  • Supports HART 5 or HART 7 communication, with long tag numbers up to 32 characters
  • Standard DIN form B head mounting for straightforward installation
  • Input/output isolated to 1500 V AC for reliable signal transmission

Genuine Yokogawa unit supplied with a one-year warranty. Please contact us for stock availability and bulk quotation.

sitemap |  Privacy Policy | China Good Quality GE Bently Nevada Supplier. Copyright © 2021-2026 GREAT SYSTEM INDUSTRY CO. LTD . All Rights Reserved.