logo
Products
PRODUCTS DETAILS
Home > Products >
Endress Hauser Proline Promag H 300 5H3B02-AAIBAEAFBAFDCS0BA2 DN2 Hygienic Electromagnetic Flowmeter PFA Liner

Endress Hauser Proline Promag H 300 5H3B02-AAIBAEAFBAFDCS0BA2 DN2 Hygienic Electromagnetic Flowmeter PFA Liner

MOQ: 1 Piece
Price: Negotiable
Standard Packaging: Original Endress+Hauser factory carton with export packing
Delivery Period: 3-5 working days for stock, 6-8 weeks for factory order
Payment Method: T/T, L/C
Supply Capacity: 50 Pieces per Month
Detail Information
Place of Origin
Germany
Brand Name
Endress Hauser
Certification
RoHs, 3-A, EHEDG
Model Number
5H3B02-AAIBAEAFBAFDCS0BA2
Product Type:
Hygienic Electromagnetic Flowmeter
Nominal Diameter:
DN2 (1/12")
Series:
Proline Promag H 300
Order Code:
5H3B02-AAIBAEAFBAFDCS0BA2
Max Measurement Error:
+/-0.5 % O.r. +/-1 Mm/s (option +/-0.2 % O.r. +/-2 Mm/s)
Medium Temperature:
-20 To +150 C (-4 To +302 F)
Max Process Pressure:
PN 40, Class 150, 20K
Liner Material:
PFA
Electrode Material:
1.4435 (316L), Alloy C22, Tantalum, Platinum
Process Connection:
Stainless Steel 1.4404, PVDF, PVC Adhesive Sleeve
Ingress Protection:
IP66/67, IP69 Hygienic Housing
Output Signal:
4-20 MA HART, Pulse/frequency, Status Output
Hygiene Approval:
3-A, EHEDG
Manufacturer:
Endress+Hauser
Warranty:
12 Months
Highlight:

Promag H 300 DN2 flowmeter

,

Hygienic electromagnetic flowmeter PFA

,

5H3B02-AAIBAEAFBAFDCS0BA2

Product Description

Proline Promag H 300 DN2 — micro-dosing and filling duty

Order code: 5H3B02-AAIBAEAFBAFDCS0BA2  |  Manufacturer: Endress+Hauser, Germany

Small hygienic lines are unforgiving: once the flow drops to a few litres per hour, an oversized meter loses resolution and the batch drifts. The DN2 build of the Promag H 300 keeps a full-bore PFA liner and a compact sensor body exactly for this band, so dosing accuracy holds at the bottom of the range and the line stays drainable after CIP.

What the DN2 size changes in practice

  • Resolution at low flow: the sensor is sized for dosing lines of roughly 3–8 mm internal diameter instead of a throttled large meter
  • Short, full-bore measuring tube leaves little product trapped between batches
  • PFA liner with stainless steel housing, no elastomer in the measuring path except the seal
  • Same transmitter as the larger sizes, so spare parts and operator training stay common across a skid

Typical duties

  • Aroma, flavour and vitamin dosing into dairy or beverage streams
  • API, media and buffer addition on pilot and small-scale bioprocess skids
  • Filling machine feed lines where each shot must be metered, not timed
  • Hygienic test benches and validation rigs that need a traceable flow signal

Checks before you place the order

  • Medium conductivity should be at least 5 µS/cm (about 20 µS/cm for demineralised water)
  • Plan straight runs of about 5 DN upstream and 3 DN downstream, and keep the tube full at zero flow
  • For plastic or lined piping, add grounding rings; empty pipe detection is available in the transmitter
  • Confirm the process connection and seal material against your existing hygienic union

Technical data

Nominal diameterDN2 (1/12")
Measuring principleElectromagnetic induction, bidirectional, full bore
Measurement error±0.5 % o.r. ±1 mm/s standard; ±0.2 % o.r. ±2 mm/s optional
Medium temperature–20 to +150 °C (–4 to +302 °F)
Max. process pressurePN 40, Class 150, 20K
LinerPFA, food grade
Electrodes1.4435 (316L); Alloy C22; tantalum; platinum
Process connectionStainless steel 1.4404 (F316L), PVDF or PVC adhesive sleeve
SealsO-ring EPDM / FKM / Kalrez; aseptic moulded seal EPDM / FKM / silicone
Ingress protectionIP66/67; hygienic housing up to IP69
Hygiene approvals3-A, EHEDG, FDA-compliant wetted materials
Outputs4-20 mA HART, pulse/frequency, status output; up to 3 I/Os
Power supply100-230 VAC or 20-30 VDC wide range
Empty pipe detectionAvailable in transmitter configuration

Scope of supply

Factory-configured instrument per order code 5H3B02-AAIBAEAFBAFDCS0BA2, with original Endress+Hauser packaging, calibration record and quick start guide. Cable length, process connection and electrode material follow the order code and can be verified by our engineers before shipment.

Data refers to the Proline Promag H 300 series; the binding configuration is the order code above.

Products
PRODUCTS DETAILS
Endress Hauser Proline Promag H 300 5H3B02-AAIBAEAFBAFDCS0BA2 DN2 Hygienic Electromagnetic Flowmeter PFA Liner
MOQ: 1 Piece
Price: Negotiable
Standard Packaging: Original Endress+Hauser factory carton with export packing
Delivery Period: 3-5 working days for stock, 6-8 weeks for factory order
Payment Method: T/T, L/C
Supply Capacity: 50 Pieces per Month
Detail Information
Place of Origin
Germany
Brand Name
Endress Hauser
Certification
RoHs, 3-A, EHEDG
Model Number
5H3B02-AAIBAEAFBAFDCS0BA2
Product Type:
Hygienic Electromagnetic Flowmeter
Nominal Diameter:
DN2 (1/12")
Series:
Proline Promag H 300
Order Code:
5H3B02-AAIBAEAFBAFDCS0BA2
Max Measurement Error:
+/-0.5 % O.r. +/-1 Mm/s (option +/-0.2 % O.r. +/-2 Mm/s)
Medium Temperature:
-20 To +150 C (-4 To +302 F)
Max Process Pressure:
PN 40, Class 150, 20K
Liner Material:
PFA
Electrode Material:
1.4435 (316L), Alloy C22, Tantalum, Platinum
Process Connection:
Stainless Steel 1.4404, PVDF, PVC Adhesive Sleeve
Ingress Protection:
IP66/67, IP69 Hygienic Housing
Output Signal:
4-20 MA HART, Pulse/frequency, Status Output
Hygiene Approval:
3-A, EHEDG
Manufacturer:
Endress+Hauser
Warranty:
12 Months
Minimum Order Quantity:
1 Piece
Price:
Negotiable
Packaging Details:
Original Endress+Hauser factory carton with export packing
Delivery Time:
3-5 working days for stock, 6-8 weeks for factory order
Payment Terms:
T/T, L/C
Supply Ability:
50 Pieces per Month
Highlight

Promag H 300 DN2 flowmeter

,

Hygienic electromagnetic flowmeter PFA

,

5H3B02-AAIBAEAFBAFDCS0BA2

Product Description

Proline Promag H 300 DN2 — micro-dosing and filling duty

Order code: 5H3B02-AAIBAEAFBAFDCS0BA2  |  Manufacturer: Endress+Hauser, Germany

Small hygienic lines are unforgiving: once the flow drops to a few litres per hour, an oversized meter loses resolution and the batch drifts. The DN2 build of the Promag H 300 keeps a full-bore PFA liner and a compact sensor body exactly for this band, so dosing accuracy holds at the bottom of the range and the line stays drainable after CIP.

What the DN2 size changes in practice

  • Resolution at low flow: the sensor is sized for dosing lines of roughly 3–8 mm internal diameter instead of a throttled large meter
  • Short, full-bore measuring tube leaves little product trapped between batches
  • PFA liner with stainless steel housing, no elastomer in the measuring path except the seal
  • Same transmitter as the larger sizes, so spare parts and operator training stay common across a skid

Typical duties

  • Aroma, flavour and vitamin dosing into dairy or beverage streams
  • API, media and buffer addition on pilot and small-scale bioprocess skids
  • Filling machine feed lines where each shot must be metered, not timed
  • Hygienic test benches and validation rigs that need a traceable flow signal

Checks before you place the order

  • Medium conductivity should be at least 5 µS/cm (about 20 µS/cm for demineralised water)
  • Plan straight runs of about 5 DN upstream and 3 DN downstream, and keep the tube full at zero flow
  • For plastic or lined piping, add grounding rings; empty pipe detection is available in the transmitter
  • Confirm the process connection and seal material against your existing hygienic union

Technical data

Nominal diameterDN2 (1/12")
Measuring principleElectromagnetic induction, bidirectional, full bore
Measurement error±0.5 % o.r. ±1 mm/s standard; ±0.2 % o.r. ±2 mm/s optional
Medium temperature–20 to +150 °C (–4 to +302 °F)
Max. process pressurePN 40, Class 150, 20K
LinerPFA, food grade
Electrodes1.4435 (316L); Alloy C22; tantalum; platinum
Process connectionStainless steel 1.4404 (F316L), PVDF or PVC adhesive sleeve
SealsO-ring EPDM / FKM / Kalrez; aseptic moulded seal EPDM / FKM / silicone
Ingress protectionIP66/67; hygienic housing up to IP69
Hygiene approvals3-A, EHEDG, FDA-compliant wetted materials
Outputs4-20 mA HART, pulse/frequency, status output; up to 3 I/Os
Power supply100-230 VAC or 20-30 VDC wide range
Empty pipe detectionAvailable in transmitter configuration

Scope of supply

Factory-configured instrument per order code 5H3B02-AAIBAEAFBAFDCS0BA2, with original Endress+Hauser packaging, calibration record and quick start guide. Cable length, process connection and electrode material follow the order code and can be verified by our engineers before shipment.

Data refers to the Proline Promag H 300 series; the binding configuration is the order code above.

sitemap |  Privacy Policy | China Good Quality GE Bently Nevada Supplier. Copyright © 2021-2026 GREAT SYSTEM INDUSTRY CO. LTD . All Rights Reserved.