| MOQ: | 1 Piece |
| Price: | Negotiable |
| Standard Packaging: | Original Endress+Hauser factory carton with export packing |
| Delivery Period: | 3-5 working days for stock, 6-8 weeks for factory order |
| Payment Method: | T/T, L/C |
| Supply Capacity: | 50 Pieces per Month |
Order code: 5H3B40-AAIBAEAFBAFDCS0BA2 | Manufacturer: Endress+Hauser, Germany
On CIP supply and return lines the meter has to survive caustic at 80 °C in one shift and cold rinse water in the next, then prove it still reads true. The DN40 version of the Promag H 300 is the size most often chosen for these circuits and for push-out of residual product before cleaning.
| Nominal diameter | DN40 (1-1/2") |
| Measuring principle | Electromagnetic induction, bidirectional, full bore |
| Measurement error | ±0.5 % o.r. ±1 mm/s standard; ±0.2 % o.r. ±2 mm/s optional |
| Medium temperature | –20 to +150 °C (–4 to +302 °F) |
| Max. process pressure | PN 40, Class 150, 20K |
| Liner | PFA, food grade |
| Electrodes | 1.4435 (316L); Alloy C22; tantalum; platinum |
| Process connection | Stainless steel 1.4404 (F316L), PVDF or PVC adhesive sleeve |
| Seals | O-ring EPDM / FKM / Kalrez; aseptic moulded seal EPDM / FKM / silicone |
| Ingress protection | IP66/67; hygienic housing up to IP69 |
| Hygiene approvals | 3-A, EHEDG, FDA-compliant wetted materials |
| Sterilisation | 150 °C / 5 bar, max. 60 min |
| Outputs | 4-20 mA HART, pulse/frequency, status output |
| CIP / SIP | Cleanable in place without removal of the sensor |
Supplied to order code 5H3B40-AAIBAEAFBAFDCS0BA2. Stock units normally ship in 3–5 working days; factory-built configurations take about 6–8 weeks. Send us the line size, medium and cleaning regime and we will confirm the option string before the order is placed.
Series data shown; final configuration follows the order code stated above.
| MOQ: | 1 Piece |
| Price: | Negotiable |
| Standard Packaging: | Original Endress+Hauser factory carton with export packing |
| Delivery Period: | 3-5 working days for stock, 6-8 weeks for factory order |
| Payment Method: | T/T, L/C |
| Supply Capacity: | 50 Pieces per Month |
Order code: 5H3B40-AAIBAEAFBAFDCS0BA2 | Manufacturer: Endress+Hauser, Germany
On CIP supply and return lines the meter has to survive caustic at 80 °C in one shift and cold rinse water in the next, then prove it still reads true. The DN40 version of the Promag H 300 is the size most often chosen for these circuits and for push-out of residual product before cleaning.
| Nominal diameter | DN40 (1-1/2") |
| Measuring principle | Electromagnetic induction, bidirectional, full bore |
| Measurement error | ±0.5 % o.r. ±1 mm/s standard; ±0.2 % o.r. ±2 mm/s optional |
| Medium temperature | –20 to +150 °C (–4 to +302 °F) |
| Max. process pressure | PN 40, Class 150, 20K |
| Liner | PFA, food grade |
| Electrodes | 1.4435 (316L); Alloy C22; tantalum; platinum |
| Process connection | Stainless steel 1.4404 (F316L), PVDF or PVC adhesive sleeve |
| Seals | O-ring EPDM / FKM / Kalrez; aseptic moulded seal EPDM / FKM / silicone |
| Ingress protection | IP66/67; hygienic housing up to IP69 |
| Hygiene approvals | 3-A, EHEDG, FDA-compliant wetted materials |
| Sterilisation | 150 °C / 5 bar, max. 60 min |
| Outputs | 4-20 mA HART, pulse/frequency, status output |
| CIP / SIP | Cleanable in place without removal of the sensor |
Supplied to order code 5H3B40-AAIBAEAFBAFDCS0BA2. Stock units normally ship in 3–5 working days; factory-built configurations take about 6–8 weeks. Send us the line size, medium and cleaning regime and we will confirm the option string before the order is placed.
Series data shown; final configuration follows the order code stated above.