| MOQ: | 1 piece |
| Price: | Negotiable, depends on channel count and module configuration |
| Standard Packaging: | Original Endress+Hauser carton with foam protection, export carton for air freight |
| Delivery Period: | 7 to 15 working days after payment |
| Payment Method: | T/T,Western Union,PayPal |
| Supply Capacity: | 80 pieces per month |
The Liquiline CM442 is a modular four-wire field transmitter that connects up to two digital Memosens sensors, freely selectable from more than twelve measurement parameters. One transmitter type covers pH, redox, ISFET, conductive and inductive conductivity, dissolved oxygen, free chlorine and other disinfection parameters, turbidity, nitrate, sludge level, SAC and fluorescence.
Because sensors are recognised automatically and exchanged with hot plug and play, a failed sensor is swapped in the field without configuration work. Universal modules and standardised spare parts are shared across the whole Liquiline platform, so a single set of spares covers the entire installed base.
| Parameter | Specification |
|---|---|
| Product type | Universal four-wire multichannel transmitter, 1 or 2 digital channels |
| Sensor interface | Memosens digital protocol, plug and play, automatic sensor recognition |
| Supported parameters | pH, redox/ORP, ISFET, conductive and inductive conductivity, dissolved oxygen, free chlorine and disinfection, turbidity, nitrate, sludge level, SAC, fluorescence |
| Channel extension | Modular, extendable at any time with universal modules |
| Housing | Robust plastic housing, base PC-FR, seal EPDM, suitable for all non-Ex applications |
| Dimensions | 237 x 194 x 162 mm (9.33 x 7.64 x 6.38 in) |
| Process temperature | -20 to +60 °C (0 to 140 °F) |
| Degree of protection | IP66 / IP67 |
| Inputs | 1 to 2 x Memosens digital; optional 2 x 0/4 to 20 mA; optional 2 x digital input |
| Outputs | 2 to 8 x 0/4 to 20 mA current outputs, alarm relay, 2 x relay |
| Communication | HART, PROFIBUS DP, Modbus RS485/RTU, Modbus TCP, EtherNet/IP, PROFINET, web server |
| Data management | SD card for software update and copy and paste of setup |
| Diagnostics | Heartbeat Technology: verification, monitoring, status-oriented maintenance |
| Hazardous area | Optional Ex module with IECEx, ATEX and CSA approvals |
| Approvals | EAC, cCSAus, MCERTS |
Configuration depends on the number of measuring channels, the parameter combination, the output and protocol modules, and whether hazardous area approval is needed. Please send the parameter list, the number of sensors, the required fieldbus and the supply voltage, and we will confirm the matching configuration and module set.
Great System Industry Co. Ltd has supplied process control instrumentation and electrical equipment since 1998, serving more than 6000 customers worldwide. All instruments ship as original factory packages with documentation.
| MOQ: | 1 piece |
| Price: | Negotiable, depends on channel count and module configuration |
| Standard Packaging: | Original Endress+Hauser carton with foam protection, export carton for air freight |
| Delivery Period: | 7 to 15 working days after payment |
| Payment Method: | T/T,Western Union,PayPal |
| Supply Capacity: | 80 pieces per month |
The Liquiline CM442 is a modular four-wire field transmitter that connects up to two digital Memosens sensors, freely selectable from more than twelve measurement parameters. One transmitter type covers pH, redox, ISFET, conductive and inductive conductivity, dissolved oxygen, free chlorine and other disinfection parameters, turbidity, nitrate, sludge level, SAC and fluorescence.
Because sensors are recognised automatically and exchanged with hot plug and play, a failed sensor is swapped in the field without configuration work. Universal modules and standardised spare parts are shared across the whole Liquiline platform, so a single set of spares covers the entire installed base.
| Parameter | Specification |
|---|---|
| Product type | Universal four-wire multichannel transmitter, 1 or 2 digital channels |
| Sensor interface | Memosens digital protocol, plug and play, automatic sensor recognition |
| Supported parameters | pH, redox/ORP, ISFET, conductive and inductive conductivity, dissolved oxygen, free chlorine and disinfection, turbidity, nitrate, sludge level, SAC, fluorescence |
| Channel extension | Modular, extendable at any time with universal modules |
| Housing | Robust plastic housing, base PC-FR, seal EPDM, suitable for all non-Ex applications |
| Dimensions | 237 x 194 x 162 mm (9.33 x 7.64 x 6.38 in) |
| Process temperature | -20 to +60 °C (0 to 140 °F) |
| Degree of protection | IP66 / IP67 |
| Inputs | 1 to 2 x Memosens digital; optional 2 x 0/4 to 20 mA; optional 2 x digital input |
| Outputs | 2 to 8 x 0/4 to 20 mA current outputs, alarm relay, 2 x relay |
| Communication | HART, PROFIBUS DP, Modbus RS485/RTU, Modbus TCP, EtherNet/IP, PROFINET, web server |
| Data management | SD card for software update and copy and paste of setup |
| Diagnostics | Heartbeat Technology: verification, monitoring, status-oriented maintenance |
| Hazardous area | Optional Ex module with IECEx, ATEX and CSA approvals |
| Approvals | EAC, cCSAus, MCERTS |
Configuration depends on the number of measuring channels, the parameter combination, the output and protocol modules, and whether hazardous area approval is needed. Please send the parameter list, the number of sensors, the required fieldbus and the supply voltage, and we will confirm the matching configuration and module set.
Great System Industry Co. Ltd has supplied process control instrumentation and electrical equipment since 1998, serving more than 6000 customers worldwide. All instruments ship as original factory packages with documentation.