| MOQ: | 1 Piece |
| Price: | Negotiation |
| Standard Packaging: | Protective foam-lined carton with mounting stud and connector cap, export carton for multi-piece orders |
| Delivery Period: | Shipped within 24 hours after payment |
| Payment Method: | T/T,Western Union,PayPal |
| Supply Capacity: | 100 pieces per month |
The Bently Nevada 190501-12-99-00 is a Velomitor CT piezo-velocity transducer, the low-frequency version of the standard Velomitor sensor, designed specifically to measure casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that run at or above 90 rpm, with 100 to 300 rpm being the typical operating band. At those speeds the rotor and fan blade vibration energy sits between 1.5 Hz and 30 Hz, exactly the region where a conventional accelerometer needs heavy integration and where a wideband velocity sensor runs out of output. The CT element holds a flat response down to 1.5 Hz, so unbalance, misalignment and blade-pass components of a slow fan reach the protection system as a clean velocity signal in millimetres per second, directly comparable with ISO 10816 evaluation zones. The transducer also captures the higher-frequency content generated by the fan motor and the speed reducer, which means one Bently Nevada sensor covers both the low-speed fan shaft and the gearbox on the same cooling tower cell.
Key Features| Parameter | Specification |
|---|---|
| Brand / model | Bently Nevada 190501-12-99-00 |
| Sensor type | Velomitor CT piezo-velocity transducer, low frequency |
| Sensitivity | 3.94 mV/mm/s (100 mV/in/s), ±5% |
| Frequency response | 3.0 to 900 Hz ±1.0 dB (180 to 54,000 cpm); 1.5 Hz to 1 kHz ±3.0 dB |
| Velocity range | 63.5 mm/s pk (2.5 in/s pk), linearity ±2% |
| Transverse response | Less than 5% of axial sensitivity |
| Mounted resonant frequency | 9 kHz minimum |
| Output bias voltage | 10.1 Vdc ±1.0 Vdc, pin A referenced to pin B (−24 Vdc system supply) |
| Dynamic output impedance | Less than 400 ohm typical |
| Broadband noise floor | 0.229 mm/s pk from 1.5 Hz to 1 kHz |
| Base strain sensitivity | 0.43 mm/s per microstrain |
| Operating temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
| Storage temperature | -40 °C to +100 °C |
| Humidity / shock | 100% condensing, non-submerged; 5000 g peak |
| Case material / height | 316L stainless steel, 82 mm (3.2 in) high, 33 mm mounting surface |
| Weight | Less than 297 g (10.5 oz) |
| Connector | 2-pin 316L MIL-C-5015, top mounted, splash proof |
| Mounting torque | 4.5 N-m ±0.6 N-m (40 in-lbf ±5 in-lbf) |
| Maximum cable length | 305 m (1000 ft) without signal degradation; 219 m recommended |
| Code A = 12 | Plate stud 3/8-24 to M8x1 mounting hardware |
| Code B = 99 | Unit with included 32 ft (9.75 m) cable |
| Code C = 00 | No agency approvals |
Cooling towers and air-cooled heat exchangers are the primary application: the fan runs slowly, the blade-pass frequency sits at a few hertz, and the steel structure transmits that energy to the bearing housing where the transducer is mounted. Installing the Bently Nevada sensor on the bearing housing or machine casing, on a machined flat pad of at least 33 mm diameter, gives the rigid mechanical path the datasheet assumes; a loose or painted mounting face reduces amplitude and frequency response and can inject false signals. The same transducer is also used on induced and forced draft fans in power generation, on slow-speed blowers in wastewater aeration, on cooling water pump trains and on gear-driven agitators. Because the output is a velocity signal, it feeds Bently Nevada 3500 series monitor channels, vibration transmitters and plant asset management systems through the two-pin MIL-C-5015 connector, and it can be left in place for continuous protection rather than hand-held route collection.
Packaging & Quality AssuranceEach transducer is supplied in protective packaging with the plate stud, mounting hardware and connector protection fitted, together with a test record confirming sensitivity and frequency response. Before dispatch we verify the output bias voltage and dynamic response of every unit, check the connector pins and insulation resistance, and confirm that the Bently Nevada model code matches the purchase order. Units are packed in foam-lined cartons with shock protection; multi-piece orders ship in an export carton and larger quantities can be palletised for project deliveries. Commercial invoice, packing list and certificate of origin are provided, and we ship by DHL, FedEx, UPS or air freight so that a protection system can be restored without waiting for a factory build slot. Send us the quantity, the required cable length and the destination port, and we will confirm stock, unit price and the fastest shipping option on the same working day. Bently Nevada interconnect cables CB2W100 in 15, 32, 64, 112, 125, 150 and 200 ft lengths, plus quick-disconnect and adaptor stud options, are available on request.
|
|
| MOQ: | 1 Piece |
| Price: | Negotiation |
| Standard Packaging: | Protective foam-lined carton with mounting stud and connector cap, export carton for multi-piece orders |
| Delivery Period: | Shipped within 24 hours after payment |
| Payment Method: | T/T,Western Union,PayPal |
| Supply Capacity: | 100 pieces per month |
The Bently Nevada 190501-12-99-00 is a Velomitor CT piezo-velocity transducer, the low-frequency version of the standard Velomitor sensor, designed specifically to measure casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that run at or above 90 rpm, with 100 to 300 rpm being the typical operating band. At those speeds the rotor and fan blade vibration energy sits between 1.5 Hz and 30 Hz, exactly the region where a conventional accelerometer needs heavy integration and where a wideband velocity sensor runs out of output. The CT element holds a flat response down to 1.5 Hz, so unbalance, misalignment and blade-pass components of a slow fan reach the protection system as a clean velocity signal in millimetres per second, directly comparable with ISO 10816 evaluation zones. The transducer also captures the higher-frequency content generated by the fan motor and the speed reducer, which means one Bently Nevada sensor covers both the low-speed fan shaft and the gearbox on the same cooling tower cell.
Key Features| Parameter | Specification |
|---|---|
| Brand / model | Bently Nevada 190501-12-99-00 |
| Sensor type | Velomitor CT piezo-velocity transducer, low frequency |
| Sensitivity | 3.94 mV/mm/s (100 mV/in/s), ±5% |
| Frequency response | 3.0 to 900 Hz ±1.0 dB (180 to 54,000 cpm); 1.5 Hz to 1 kHz ±3.0 dB |
| Velocity range | 63.5 mm/s pk (2.5 in/s pk), linearity ±2% |
| Transverse response | Less than 5% of axial sensitivity |
| Mounted resonant frequency | 9 kHz minimum |
| Output bias voltage | 10.1 Vdc ±1.0 Vdc, pin A referenced to pin B (−24 Vdc system supply) |
| Dynamic output impedance | Less than 400 ohm typical |
| Broadband noise floor | 0.229 mm/s pk from 1.5 Hz to 1 kHz |
| Base strain sensitivity | 0.43 mm/s per microstrain |
| Operating temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
| Storage temperature | -40 °C to +100 °C |
| Humidity / shock | 100% condensing, non-submerged; 5000 g peak |
| Case material / height | 316L stainless steel, 82 mm (3.2 in) high, 33 mm mounting surface |
| Weight | Less than 297 g (10.5 oz) |
| Connector | 2-pin 316L MIL-C-5015, top mounted, splash proof |
| Mounting torque | 4.5 N-m ±0.6 N-m (40 in-lbf ±5 in-lbf) |
| Maximum cable length | 305 m (1000 ft) without signal degradation; 219 m recommended |
| Code A = 12 | Plate stud 3/8-24 to M8x1 mounting hardware |
| Code B = 99 | Unit with included 32 ft (9.75 m) cable |
| Code C = 00 | No agency approvals |
Cooling towers and air-cooled heat exchangers are the primary application: the fan runs slowly, the blade-pass frequency sits at a few hertz, and the steel structure transmits that energy to the bearing housing where the transducer is mounted. Installing the Bently Nevada sensor on the bearing housing or machine casing, on a machined flat pad of at least 33 mm diameter, gives the rigid mechanical path the datasheet assumes; a loose or painted mounting face reduces amplitude and frequency response and can inject false signals. The same transducer is also used on induced and forced draft fans in power generation, on slow-speed blowers in wastewater aeration, on cooling water pump trains and on gear-driven agitators. Because the output is a velocity signal, it feeds Bently Nevada 3500 series monitor channels, vibration transmitters and plant asset management systems through the two-pin MIL-C-5015 connector, and it can be left in place for continuous protection rather than hand-held route collection.
Packaging & Quality AssuranceEach transducer is supplied in protective packaging with the plate stud, mounting hardware and connector protection fitted, together with a test record confirming sensitivity and frequency response. Before dispatch we verify the output bias voltage and dynamic response of every unit, check the connector pins and insulation resistance, and confirm that the Bently Nevada model code matches the purchase order. Units are packed in foam-lined cartons with shock protection; multi-piece orders ship in an export carton and larger quantities can be palletised for project deliveries. Commercial invoice, packing list and certificate of origin are provided, and we ship by DHL, FedEx, UPS or air freight so that a protection system can be restored without waiting for a factory build slot. Send us the quantity, the required cable length and the destination port, and we will confirm stock, unit price and the fastest shipping option on the same working day. Bently Nevada interconnect cables CB2W100 in 15, 32, 64, 112, 125, 150 and 200 ft lengths, plus quick-disconnect and adaptor stud options, are available on request.