Measurement Range: | 0 To 400 HPa | Process Temperature: | -5 To 60 °C (20 To 140 °F) |
---|---|---|---|
Process Pressure: | Max. 10 Bar Abs (Max. 145 Psi) | Order Code: | COS61D-AAA1A3 |
Product Name: | Oxymax COS61D | Approval: | Non-hazardous Area |
Application/Measuring Range: | Oxygen 0...20mg/l | Sensor Adaption: | Fixed Cable; Crimp Sleeves |
Description:
Memosens optical oxygen sensor for water, wastewater and utilities
Product name : Oxymax COS61D
Order code : COS61D-AAA1A3
AA-Approval : Non-hazardous area
A1-Application/Measuring Range : Oxygen 0...20mg/l
A-Sensor Adaption : Fixed cable; crimp sleeves
3-Cable length:7m
Weight
With cable length 7 m (23 ft): 0.7 kg (1.5 lbs.)
With cable length 15 m (49 ft): 1.1 kg (2.4 lbs.)
Materials
Process connection: G1, NPT 3/4"
Sensor cable : shielded 4-core fixed cable
Cable connection to the transmitter
• Terminal connection
• optional: M12 plug
Maximum cable length : max. 100 m (330 ft, (including cable extension))
Temperature compensation : internal
Actual Dimension Standard Packing Box : 37 X 35 X 70 cm
Shipping Weight : 5.2 Kg
Additional Informaiton:
Memosens optical oxygen sensor for water, wastewater and utilities
Oxymax COS61D is a high-performance, digital oxygen sensor that offers fast, accurate and drift-free measurement. It supports your process with low maintenance, high availability and easy handling. The sensor's long-term stable fluorescence layer is exclusively oxygen-selective (interference-free), ensuring consistently reliable measurement. Thanks to Memosens digital technology, the Oxymax COS61D combines maximum process and data integrity, and facilitates simple lab calibration.
Benefits
Minimum maintenance, maximum availability
Fast, drift-free measurement for precise aeration control and process monitoring
Long-term stability for increased process safety
Outstanding performance in all aeration processes (SBR, Anamox, etc.)
Chemical-free: no electrolyte handling
Show less
Field of application
Oxymax COS61D measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
Fish farming:
- O2 control for optimum growth conditions
Show less
Features and specifications
Oxygen
Measuring principle
Optical oxygen measurement
Application
Aeration tank, river monitoring, water treatment, fish farming
Characteristic
Common Models:
CLM223-CD0005 | CPS11D-7BT21 | FMU40-ANB2A2 | FTL50 |
CLM253-CD0005 | CKY10-A101 | FMB53-AA21JA1FGB15B3A | FTL50H |
COM223-DX0005 | CPM253-MR0105 | FMI52-A1AB3KB5A1A | FTL51 |
COM253-WX0005 | CPA250-A00 | 50H50-1F0B1AA0ABAA | FTL51C |
COM253-DX0005 | CPS11-2BT2ESA | FMR231-AFCQKAA4CA | FTL51H |
CPM223-MR0005 | CPF81D-7LH11 | PMP131-A2B01A1W | FTL70 |
CPM253-MR0005 | FTL31-AA4U3BAWSJ | PMC131-A15F1A1K | FTL71 |
CPM223-PR0005 | CLS15 | PMC71 PMP71PMP75 | FMU30 |
CPM253-PR0005 | CLS21 | PMC45-RE11F2A1K11 | FMU40 |
COS41-2F | CUS31 | PMC45-RE11F2A1AL1 | FMU41 |
COS41-4F | COS41 | PMC45-RE11H2A1AL1 | FMU42 |
COS61-A1F0 | CPS11D-7BA21 | PMC45-RE11P1C1AH4 | FMU43 |
COS61-A2F0 | CCM253-EK0005 | PMC45-RE11M2A1AL1 | FMU44 |
COS61D-AAA1A3 | CUM223/253 | PMC45-RE11H3H1DL4 | FMU95 |
CPS11D-7AA21 | CLM223/253 | PMC131-A15F1A1R | FMU90 |
CPS11D-7BA2G | CPS41-1AC2SSA | PMC131-A15F1D14 | FMR230 |
CPS11D-7BA41 | CLS21-C1E4A | PMC131-A15F1A1S | FMR231 |
FTM51-AGG2M4A32AH | CLS21-C1N2A | PMC131-A15F1A1G | FMR240 |
FTM51-AGG2M4A32AH L=500mm | CLS21-C1N3A | PMC131-A15F1A1Q | FMR244 |
CPS11D-7AS21 | CLS15-B1M2A | PMP131-A1401A1S | FMR245 |
CPS11D-7BT2G | CLS15-A1M2A | PMC71-ANA1S2GHAAA | FMR250 |
CPS12D-7NA21 | CLS15-A3D1A | PMC71-ANA1P2GHAAA | FMR530 |
Contact Person: Mrs. Joanna Yang
Tel: +86-13828861501
Fax: 86-755-26850713